How Our Assessment Works

An automated visual assessment grounded in published national standards.

What this tool does

When you submit a photo of a utility pole, our AI analyzes it for visible condition factors that professional inspectors also evaluate. Each factor is assessed as appears normal, warrants attention, or warrants inspection. These factor-level observations are combined into an overall 1-10 condition score.

The assessment references published national standards used by utility inspectors, safety agencies, and regulators across the United States. We cite the specific standard for each factor we evaluate.

What we check

Factor What we look for Standard
Lean Visible tilt from vertical OSHA 1910.269 App. D
Ground-line decay Rot, splintering, diameter loss at the base OSHA App. D; ANSI O5.1
Vegetation Trees or vines in contact with conductors or pole NESC Rule 218
Cross-arm condition Cracked, rusted, or drooping cross-arms FIST 4-6
Hardware Hanging wires, broken insulators, detached components FIST 4-6
Weathering Surface cracks, splits, checking OSHA App. D
Woodpecker damage Holes that reduce cross-section strength OSHA App. D
Abandoned status No active wires or apparent purpose NESC Rule 214
Guy-wire dependency Pole requires support to remain upright FIST 4-6
Base damage Soil erosion, vehicle impact, animal damage OSHA App. D

What this tool cannot tell you

A photo-based assessment has real limitations. The following require a professional field inspection and cannot be determined from a photograph:

How the score is calculated

The overall 1-10 condition score is derived from the individual factor assessments, not from a single overall impression. The derivation:

One thing we track separately. When a pole is carrying an unusually high number of line attachments, or has communication lines that appear dead or abandoned, we note that as its own observation and show it on the pole page. It is not part of the 1-10 condition score. Abandoned lines are a coordination problem between the utility and the cable or phone companies that attach to its poles, not a sign that the pole itself is structurally unsound, so we keep it out of the condition rating on purpose.

The recommended action

Each pole is also mapped to one of three citizen-facing action tiers, based on the same factor observations:

These are observations, not diagnoses. They describe what a citizen can see in the photo and what the utility's normal inspection process would do with that observation. They are not a determination of structural adequacy.

Standards we reference

This methodology was designed by Chris Justin, a licensed Professional Engineer (Louisiana) and former consultant to the Public Service Commission — the same inspection factors the Commission's own staff report flagged, applied to photos anyone can take.

This is an automated visual assessment based on a single photograph. It is not a professional inspection. A complete pole condition assessment requires a field inspection including internal testing (hammer-and-bore or sonic), load analysis, and clearance measurement. If a pole appears hazardous, contact your utility company immediately.

Limitation of liability: This assessment is provided for informational and advocacy purposes only. It is provided "as is" without warranty of any kind. Do not rely on this assessment for safety-critical decisions, maintenance planning, or any determination of structural adequacy. The operators of this site assume no liability for any actions taken or not taken based on these assessments. A qualified utility inspector or licensed professional engineer should evaluate any pole that may pose a safety concern.